• Trainer For The Study Of The Semi Hermetic Compressor Refrigeration Trainer Teaching Equipment Vocational Training Equipment
  • Trainer For The Study Of The Semi Hermetic Compressor Refrigeration Trainer Teaching Equipment Vocational Training Equipment

Trainer For The Study Of The Semi Hermetic Compressor Refrigeration Trainer Teaching Equipment Vocational Training Equipment

No.ZM6120

ZM6120 Trainer For The Study Of The Semi Hermetic Compressor Refrigeration Trainer Teaching Equipment Vocational Training Equipment

Input power
Three phases five wires AC380V±10%, 50Hz
Operating condition
environment temperature 10℃~30℃, relative humidity <75% (25℃)
  • Trainer For The Study Of The Semi Hermetic Compressor Refrigeration Trainer Teaching Equipment Vocational Training Equipment

Description

ZM6120 Trainer For The Study Of The Semi Hermetic Compressor Refrigeration Trainer Teaching Equipment Vocational Training Equipment
I. Product overview
The training device is used for the study of semihermetic compressor running features, students can understand the appearance of the open type compressor through the training device, operation mode, the refrigeration effect, etc. Semihermetic compressor is controlled by inverter, compressor rotation speed can be adjusted. It’s suitable for skill appraisal, evaluation work, higher vocational colleges, vocational schools cooling technology, and household refrigeration equipment principle and maintenance and refrigeration equipment repair and so on teaching practice.
II. Product feature
The training bench takes aluminum frame structure, it is concise and fastness, it is not only to lighten the equipment, but also ensure the strength of equipment, it is equipped with 4 universal casters on its bottom, which is easy to move.
The refrigeration circulation pipeline is laid on installation panel, it is painted with different colors on high and low temperature area, which is easy for observation and distinguish.
The equipment is fitted with good safety protection system. It is equipped with highlow pressure protection switch in refrigerating cycle, when system pressure is abnormal, the compressor can stop work immediately to protect compressor and system. It is equipped with earth leakage circuit breaker, emergency stop and reliable ground protection in electrical circuit, which is to ensure safety of equipment and personal.
Supply software which can monitor voltage, current, frequency, power, power factor, 
pressure, flow, etc, they can be displayed on PC in real time, and can print report.
III. Technical data
(1) Input power: Three phases five wires AC380V±10%, 50Hz
(2) Overall dimension: 1400mm×800mm×1800mm
(3) Weight: 100kg
(4) Operating condition: environment temperature 10℃~30℃, relative humidity <75% (25℃)
Supplied with:
English General Refrigeration manual 
English Experimental Manual