ZM6161 Inverter Air Conditioner Trainer Cooling Heating Trainer
ZM6161 Inverter Air Conditioner Trainer Cooling Heating Trainer. Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Fluid Lab Equipment,air conditioner trainer, refrigeration trainer, Thermal Lab Equipment, Vocational Training Equipment,Didactic Equipment,Engineering Educational Equipment,Technical Teaching Equipment,for university,college,technical institution, polytechnics.Should Shine products has been exported to America,Asia,Europe,Africa, Australia.
- Description
- Inquiry
ZM6161 Inverter Air Conditioner Trainer Cooling Heating Trainer
Picture is only for reference, we supply as technical data
I Introduction
This trainer is designed for the in-depth study of vapour-compression cycle. It enables to vary the load conditions of condenser and of evaporator, to use alternative devices for gas expansion, to handle successfully unexpected operating situations, such as the block of the refrigerant flow or a wrong gas charge inside the circuit. Students can become familiar with the refrigerant pressure-enthalpy diagram and evaluate the heat balances corresponding to the different cycle components, by using the set of industrial instruments of the equipment.
R410 environmental refrigerant, refrigeration effect 12000BTH/h
Single phase 220V to 240V, 50Hz
1 units condenser and 1 units remote control
Sight glass on external liquid & gas lines
H&L pressure gauge, manual hand valve
Instrument and control panel, with dig., volt meter, ampere meter, dig. Wattmeter, on/off control, ELCB,MCB, protec.circuit etc.
Fan coil unit mounted onto board
Condenser unit mounted onto floor or f the framework
The unit is suplied with all material required for installation
Supply with wheels and castors
Supply all necessary spare parts, intallation tools
Floor trap tray
Aluminum( which is better than steel), corrosion resistant outer casting stand
II Training Program
Plant starting and safety devices intervention checking
Studying the operation of a thermostatic expansion valve
Analyzing the system behaviour versus the variation of:
– Expansion device
– Superheat (when the thermostatic expansion valve is used)
– Air flow rate at condenser and/or evaporator
– Refrigerant charge into the system
Plotting the cycle in the refrigerant pressure-enthalpy diagram
Data acquisition and calculation of:
– Thermostatic valve superheat
– Heat balances corresponding to evaporator, condenser, compressor
– Refrigerant mass flow
– Ideal and actual efficiency
– Volumetric compression efficiency
Supplied with:
English General Refrigeration Manual
English Experimental Handbook
– Ideal and actual efficiency
– Volumetric compression efficiency
Supplied with:
English General Refrigeration Manual
English Experimental Handbook