SS5001 Milk Normalization and Pasteurization Food Machine Trainer
SS5001 Milk Normalization and Pasteurization Food Machine Trainer. Jinan Should Shine Didactic Equipment Co., Ltd. is company specialized in manufacture and trading Fluid Lab Equipment,air conditioner trainer, refrigeration trainer, Thermal Lab Equipment, Vocational Training Equipment,Didactic Equipment,Engineering Educational Equipment,Technical Teaching Equipment,for university,college,technical institution, polytechnics.Should Shine products has been exported to America,Asia,Europe,Africa, Australia.
- Description
- Inquiry
SS5001 Milk Normalization and Pasteurization Food Machine Trainer
1 Product overview
1.1 Overview
Fresh milk pasteurization machine widely suitable for the determine and update of original fresh milk, yoghourt, ewe’s milk, camel milk, fruit juice, milk beverage, condiment and other product, the screening of product taste, the assessment of colour, the application of stabilizer and emulgator. The research and development and sample making of new product. It is the ideal equipment of college and university, milk bar, minitype pasteurised milk manufacturer. It can be used in any multiple tank combination according to requirement. It is very suitable for the using of short run multispecies of small and medium size dairy products.
In a range of temperature, the lower temperature, the slower bacterial reproduction, the higher temperature, the faster bacterial reproduction( the preference temperature of general microbial growth is 28℃-37℃), if the temperature is too high, bacterial will die. Different bacterial have different optimum growth temperature and heat-resisting, cold tolerance ability. Pasteurization take advantage of the characteristic of causative agent not heat-resisting, use the appropriate temperature and soaking time, it will kill all the bacterial. But after pasteurization, it still retain fraction innocuity or conduce, relative heat-resisting bacterial and bacterial spore, so the preserve of pasteurization milk must under around 4℃, and it only can preserve 3-10 days, at most 16 days.
1.2 Characteristic
1) All the contact parts adapt SUS304/SUS316Lstainless steel, drivepipe gasket and sealing element adapt food grade silicone rubber, the connection of product pipe fitting, this accords with the national health authorities required food safety testing standards.
2) Health level pump cycle.
3) it can select steam heating and electrical heating.
4) Three layers tin with jacket, polyurethane as the thermal insulation material.
5) External connect to ice water and tap water for chilling the product.
6) It has the advantage of sterilizing effect is good, small noise, speed can adjustable, wear well, safe and reliable, temperature can automatic control and adjust, easy to operation.
7) All the component on the stainless steel frame, easy to move on, easy maintenance,etc.
8 It can provide custom design according to the requirement details.
2 Performance parameter
(1)Input power supply: two phase three wires system 220V±10% 50Hz
(2) Boundary dimension: 1200mm×800mm×1600mm
(3)Heating power: 6KW, centrifugal pump power: 0.75KW
(4)Min. Single tin inventory 10-20L, max. Single tin inventory:500L
(5)Temperature control±1℃: it can control temperature and adjust the sterilization temperature according to requirement.
(6)Sterilizing time: it can set the sterilizing time according to requirement.
(7)Circulation power: health level centrifugal pump circulation heat transfer.
(8)Timing system: sterilization timing.
(9)Sterilization working condition: totally closed sterilization.
(10)Equipment texture: tank is high quality SUS304/316L stainless steel.
(11)Weight: <260kg
(12)Working condition: environment temperature -10℃~+40℃
3 Product installation instructions
3.1 Pasteurization machine classification
1)According to structure: single tin pasteurization unit, double tin pasteurization unit.
2)According to heating form: steam heating pasteurization machine, electrical heating pasteurization machine.
3.2 The advantage of pasteurization machine
The principle of sterilization is in the certain range of temperature, the lower temperature, the slower bacterial reproduction, the higher temperature, the faster bacterial reproduction, if the temperature is too high, bacterial will die. Different bacterial have different optimum growth temperature and heat-resisting, cold tolerance