ZM3186 Model of Lift (Complete Set with PLC) Educational Equipment Lift Trainer
- Elevator trainer should allow users to carry out experiments about control program, structure and principal of baggage lift and passenger’s elevator;
- It should use real three-phase induction motor with electronic controlled breaker like a real elevator;
Experiments to be Performed:
- CAR’s winding machine operation exercise
- CAR’s location indication exercise
- Winding machine’s automatic stop exercise
- CAR’s high / low limit driving exercise
- Winding machine’s operation exercise
- Freight elevator’s call exercise
- Passenger elevator’s operation exercise
Technical Parameters:
Induction Motor:
- Voltage: 3Ø AC, 50/60Hz
- Rating: Continuous
- Capacity: 25W
- Brake: Electronic brake
- Reduction Gear: 30:1
Machine Structure:
- Type: 3 floor, steel move type
- Doors: 3 doors
- Car balancer: 1 Set
- Caster: 4 EA (Locking: 2 EA)
Electro Structure:
- Electronic magnetic: FOR / REV
- Limit switch: 8 EA
- MCCB (30AF, 20AT): 1EA
- Buzzer: 1EA
- Terminal point: 57 point
- Push-Button switch: 15 EA
- Pilot lamp: 9 EA
- Standard accessories with printed operation manual
The elevator trainer (model of lift) should be supplied with following PLC trainer for proper controlling (Quantity-01 set):
CPU of PLC Unit:
- Control Method: Cyclic execution of stored program, Time-driven operation, Interrupt task operation.
- I/O Control Method: Scan synchronized batch processing method (Refresh Method)
- Program Language: LD(Ladder Diagram), IL (Instruction List), SFC(Sequential Function Chart)
- Number of Instructions: LD(20EA), IL(13EA), SFC(194 EA)
- Processing Speed: 0.2/Step
- Program Memory Capacity: 128 Kbyte
- Maximum I/O Points: 512 points (With 16-pt modules), 1024 points (With 32-pt modules), 2048 points (With 64-pt modules)
Digital Input:
- Input Point: 16 Points (2 EA)
- Rated Input Voltage: DC 12/24V
- Common Method: 8 Points/1 Com
- Insulation Method: Photo Coupler Insulation
Digital Output:
- Output Point: 16 Points (2 EA)
- Rated Load Voltage: DC 12V, AC 220V
- Rated Load Current: Max 2A
- Common Method: 8 Points/1Com
- Insulation Method: Relay Insulation
- Power Module: AC 50Hz/60Hz; DC 5V/4A, 24V/0.7A
- Vibration Proof Module: Vibration proof for non-use slot
- Base: 8 slot (Maximum Number of Module Attach 8 EA)
Trainer Power Supply:
- Power: AC, 50Hz/60Hz
- Meter: 1 EA
- Main Power (Built-in Current Protection Device): 1 Unit
- P.L.C. Power (Built-in Current Protection Device): 1 Unit
- DC output power (DC 24V): 1 Unit
- Output Terminal: 4 EA
Sensor Input and Motor Device:
- DC Motor (DC 24V): 1 Unit
- Coupling: Circular Type (Hole 4 EA/Magnetic 1 EA)
- Photo Sensor (Detection Distance: 200mm): 1 EA
- Proximity Sensor (Detection Distance: 8mm): 1 EA
- Power for Sensor: DC 12V~24V
Input Signal Device:
- Non Lock Type Push Button: 7 EA
- Lock Type push button: 1 EA
- Digital Switch (BCD, 2 Digits): 1 Unit
Output Signal Indication:
- Output Lamp (DC 24V):7 EA
- Buzzer (DC 24V): 1 EA
- Segment Display (BCD, 2 Digits): 1 Unit
Digital I/O Terminal:
- Input: 32 Points (16 Points/1 COM Total 4EA)
- Output: 32 Points (16 Points/1 COM Total 4EA)
- Standard accessories with printed operation manual